Authors
Fengzhi Dai1, 2, 3, *, Yuxuan Zhu1, 3, Di Yin1, Yasheng Yuan1
1College of Electronic Information and Automation, Tianjin University of
Science and Technology, Tianjin 300222, China
2Department of Technology Development, Tianjin Tianke Intelligent and Manufacture
Technology Co. Ltd.,Tianjin, China
3Advanced Structural Integrity International Joint Research Centre, Tianjin
University of Science and Technology, Tianjin 300222, China
*Corresponding author. Email: [email protected]
Corresponding Author
Fengzhi Dai
Received 25 October 2019, Accepted 19 February 2020, Available Online 14
May 2020.
DOI
https://doi.org/10.2991/jrnal.k.200512.003
Keywords
VIENNA rectifier; model systems; voltage imbalance; simulate; working principle
Abstract
This paper analyzes the working principle of VIENNA rectifier and establishes
the transformation model of rectifier in three different mathematical coordinate
systems. First is to obtain the control structure of the converter, which
is a double closed loop control structure (the voltage is the outer loop
control and the current is the inner loop control). By using a feed forward
control strategy to solve the problem of phase-to-phase coupling. By adding
the voltage equalization loop and using the midpoint balance algorithm
to solve the problem of the voltage imbalance caused by the rectifier under
load. Finally, uses MATLAB to build the model, simulates and verifies the
established model system.
Copyright
© 2020 The Authors. Published by ALife Robotics Corp. Ltd.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license
(http://creativecommons.org/licenses/by-nc/4.0/).